Product introduction
Mining explosion-proof lithium-ion battery power supply
礦用隔爆型鋰離子蓄電池電源
礦用隔爆型鋰離子蓄電池電源將*的鋰電池配組技術、
充放電管理技術、均衡技術與隔爆技術,通信總線技術、顯示技術等融為一體,
為用電設備提供穩定可靠的后備電力供應。
The mining explosion-proof lithium-ion battery power supply integrates advanced lithium battery assembly technology,
charge and discharge management technology, equalization technology, explosion-prooftechnology, communication bus technology, display technology, etc.,
providing stable and reliable backup power supply for electrical equipment.
礦用隔爆型鋰離子蓄電池電源適用于煤礦井下有瓦斯、煤塵等爆炸性氣體的危險環境中,
可作為礦用救生艙、避難硐室、井下通信設備供電、井下照明等需礦用
127V、220V交流不間斷供電的應用場合。
The mine explosion-proof lithium-ion battery power supply is suitable for the dangerous environment with gas,
coal dust and other explosive gases in the coal mine. It can be used as the application field of mine life-saving cabin, refuge chamber,underground communication equipment power supply,
underground lighting and other applications requiring mining 127V, 220V AC uninterruptible power supply.
Model meaning
Mining explosion-proof lithium-ion battery power supply
礦用隔爆型鋰離子蓄電池電源
Functional characteristics
Mining explosion-proof lithium-ion battery power supply
礦用隔爆型鋰離子蓄電池電源
支持四種井下輸入電壓( AC660V、380V、220V、127V)
Support four kinds of downhole input voltage (AC660V, 380V, 220V, 127V)
電源隔離,優化輸出電源,隔離電網中的污染源
Isolation of power supply, optimization of output power supply and isolation of pollution sources in power grid
內部模塊化設計,無縫式備用電池切換
Internal modular design, seamless backup battery switching
智能電池管理系統,鋰電池壽命
Intelligent battery management system to maximize the life of lithium battery
支持多種接口輸入、輸出不間斷高質量穩壓電能
Support a variety of interfaces to input and output uninterruptedly high-quality regulated power
網絡化管理平臺設計方案,實現遠程監控管理功能,支持遠程放電
Design scheme of network management platform to realize remote monitoring management function and support remote discharge
過溫保護、過沖保護、過放保護、充電過流保護、輸出短路保護、過流保護
Over temperature protection, over impulse protection, over discharge protection, charging over-current protection, output short circuit protection, over-current protection
備用電源一體化解決方案,大大簡化系統結構,節約成本
Integrated solution of standby power supply greatly simplifies system structure and saves cost
Shape structure
Mining explosion-proof lithium-ion battery power supply
礦用隔爆型鋰離子蓄電池電源
基本外形結構
Basic shape structure
本電源機械尺寸為(mm):715(長)×536(寬)×875(高);具有6個喇叭 口:電源輸入1個、電源輸出1個、以太網接口1個,還有2個備用通信接口;一個L CD液晶顯示屏;一個電源開關;電源防爆箱分為鋰離子蓄電池組模塊腔、管理與控 制系統腔和接線腔3個腔體。 重量:255±2 Kg。
The mechanical dimension of the power supply is (mm): 715 (L) × 536 (W) × 875 (H); it has six bellmouth: one power input, one power output, one Ethernet interface, and two standby communication interfaces; one LCD screen; one power switch; the power explosion-proof box is divided into three cavities: module cavity, management and control system cavity and wiring cavity. Weight: 255 ± 2 kg.
基本外形結構
Basic shape structure
1— 電池腔端蓋
2— 蓋板提手(僅用于提取蓋板,勿用于提取整套電源)
3— 煤安標志
4— 防爆標志
5— 顯示屏
6— 前面板把手
7— 產品規格銘牌
8— 接地銘牌
9—逆變開關(打開或關閉逆變功能)
10—電源吊起把手(用于提取整套電源)
11—電源提手(用于電源挪動,不能用于吊起整套電源)
12—交流電源輸入端口(包括660V、127V交流輸入)
13—交流電源輸出端口(127V交流輸出)
14—備用通信接口
15—以太網通信接口(光纖)
16—備用通信接口
17—接線腔端蓋
內部接線端子
Internal terminal block
Troubleshooting
Mining explosion-proof lithium-ion battery power supply
礦用隔爆型鋰離子蓄電池電源
常見故障、產生原因及其排除方法參見以下表格:
| 故障現象 | 故障原因 | 排除方法 |
| 無輸出 | 開關未開啟 | 開啟開關 |
| 輸出有短路現象 | 排除輸出短路 |
Precautions for use
Mining explosion-proof lithium-ion battery power supply
礦用隔爆型鋰離子蓄電池電源
使用前準備
1、安裝使用前,必須認真閱讀本使用說明。
2、在接通電源前,請仔細檢查各腔體面蓋,確保各腔體已 經嚴格密閉。
3、電源外部的逆變開關為逆變功能控制開關,用于開啟或 關閉逆變功能,不是整個電源的開關。
按照以下步驟使用:
步:接通外部供電,此時電源處于正常工作狀態。
第二步:合上電源上的逆變開關,使電源UPS功能開啟。
注意事項
1、嚴禁將本產品與沒有經過檢驗并未取得防爆合格證的設備
配套使用。如需配套使用應經防爆檢驗部門檢驗合格后方可
使用。
2、電源在井下現場需要開蓋時,必需切斷外部輸入電源并斷
開電源的逆變開關。否則檢修時內部產生的火花有可能引起瓦
斯爆炸。
3、電源箱安裝、接線必須嚴格按照煤礦安全規程進行。
4、本產品禁止劇烈震動、摔、碰。
5、本系統長期不工作時必須斷開電源和逆變開關。
6、本系統電池組長期不使用時,應需每隔2個月進行一次
充、放電操作:電源正常工作過程中,關閉交流電源輸入,
由電池組逆變供電到欠壓保護為止。然后再接上交流輸入電
源,使電源恢復正常工作,并給電池組充電,以保持電池活
性。
Technical parameter
Mining explosion-proof lithium-ion battery power supply
礦用隔爆型鋰離子蓄電池電源
| 項目 | DXBL1536/127J | DXBL1536/220J | DXBL2880/127J | DXBL2880/220J |
| 電池標稱容量 | 40Ah | 40Ah | 60Ah | 60Ah |
| 電池額定充電電壓 | 2.5V | 2.5V | 6V | 6V |
| 電池組充電過流保護值 | 6A | 6A | 8A | 8A |
| 電池組額定放電電流 | 8A | 8A | 15A | 20A |
| 電池組放電過流保護值 | 12A | 12A | 20A | 40Ah |
| 電池組的允許使用容量報警值 | 28Ah | 28Ah | 40Ah | 127V |
| 電源額定輸出電壓 | 127V | 220V | 127V | 220V |
| 電源額定輸出電流 | 2.5A | 1.5A | 5A | 3A |
| 電源輸出短路保護 | ≤50ms | ≤50ms | ≤50ms | ≤50ms |
| 電源額定輸入電壓范圍 | 660V/127V(-25%~10%) | 660V/127V(-25%~10%) | 660V/127V(-25%~10%) | 660V/127V(-25%~10%) |