Electronic Pressure transmitter for medical gases |
The given measuring ranges are also available in kg/cm2, MPa and kPa.
Vacuum and +/- measuring ranges are also available.
Vacuum resistance
Yes
Output signals

Accuracy
Accuracy at reference conditions
≤ ±2 % of span
Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2).
Calibrated in vertical mounting position with process connection facing downwards.
Non-linearity
≤ 0.5 (BFSL per IEC 61298-2)
Temperature error
≤ ±2.0 % of span
Long-term drift (per IEC 61298-2)
≤ 0.3 % of span/year
Settling time
≤ 2 ms
Voltage supply
The permissible power supply depends on the corresponding output signal.

Total current consumption maximum 10 mA (except for 2-wire signals)
Operating conditions
Ingress protection (per IEC 60529)
IP 67
The stated ingress protection only applies when plugged in using a mating connector that has the appropriate ingress protection.
Vibration resistance
20 g (20 ... 2,000 Hz, 2 h) per IEC 60068-2-6 (vibration under resonance)
Shock resistance
40 g (6 ms) per IEC 60068-2-27 (mechanical shock)
Temperatures
Reference conditions (per IEC 61298-1)
Temperature
15 ... 25 °C
Atmospheric pressure
860 … 1,060 mbar (665 ... 800 mmHg)
Humidity
45 ... 75 % relative, non-condensing
Power supply
DC 24 V
DC 5 V with ratiometric output
Mounting position
as required
Process connections

Electrical connections
Short-circuit resistance
S+ vs. 0V
Reverse polarity protection
UB vs. 0V
Insulation voltage
DC 500 V
Connection diagrams


Cleanliness specifications
Packaging
For the individual levels of cleanliness of the model MG-1 the following types of packaging are available.

Materials
Wetted parts
Process connection from stainless steel 316L and 13-8 PH
Sealing ring from FKM (if available)
Non-wetted parts
Case from stainless steel 316L
Electrical connection from highly resistant, glass-fibre reinforced plastic PBT GF 30
Approvals, directives and certificates
CE conformity
EMC directive 2004/108/EC, EN 61326 emission (group 1, class B) and immunity (industrial application)
Pressure equipment directive 97/23/EC
Dimensions in mm
Pressure transmitter
Process connections


Ordering information
Model / Measuring range / Output signal / Electrical connection / Process connection / Level of cleanliness / Type of packaging